Event code
Event name
5401560D hex
Parameter
Selection Out
of Range
5401560E hex
CNC Param-
eter Setting
Read/Write
Setting Value
Out of Range
5401560F hex
CNC Param-
eter Setting
Read/Write
Target Out of
Range
54015611 hex
Homing
Parameter
Setting Out of
Range
54015612 hex
M Code
Number Out
of Range
54015613 hex
CNC Instruc-
tion Re-exe-
cution
Disabled
(CNC Coordi-
nate System
Specification)
54015614 hex
CNC Instruc-
tion Re-exe-
cution
Disabled
(Logical CNC
Motor Num-
ber)
5401561D hex
SD Memory
Card Access
Failure
5401561E hex
File Does Not
Exist
NJ/NX-series Troubleshooting Manual (W503)
Meaning
Assumed cause
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
ParameterNumber
input variable.
input variable to a
CNC instruction is
out of range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
SettingValue in-out
in-out variable.
variable to a CNC
instruction is out of
range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
Target in-out vari-
in-out variable.
able to a CNC
instruction is out of
range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
HomingParameter
in-out variable.
in-out variable to a
CNC instruction is
out of range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
MCodeNo input
input variable.
variable to a CNC
instruction is out of
range.
An attempt was
• A parameter for an in-out vari-
made to change the
able that cannot be changed for
parameter for the
re-execution was changed.
Coord in-out vari-
able when re-exe-
cuting a CNC
instruction. (This in-
out variable cannot
be changed when
re-executing an
instruction.)
An attempt was
• A parameter for an input vari-
made to change the
able that cannot be changed for
parameter for the
re-execution was changed.
LogicalMotorNo
input variable when
re-executing a CNC
instruction. (This
input variable can-
not be changed
when re-executing
an instruction.)
SD Memory Card
• An SD Memory Card is not
access failed when
inserted.
an instruction was
• The SD Memory Card is dam-
executed.
aged.
• The SD Memory Card slot is
broken.
The file specified
• The specified file does not
for an instruction
exist.
does not exist.
3 Error Tables
Level
Maj
Prt
Min
Obs Info
S
O030
S
O030
S
O030
S
O030
S
O030
S
O030
S
O030
S
O030
S
O030