Omron NX701-17 Series Troubleshooting Manual page 297

Machine automation controller nj/nx-series
Hide thumbs Also See for NX701-17 Series:
Table of Contents

Advertisement

Event code
Event name
781A0000 hex
Setting Data
Transfer
Error
781B0000 hex
Output Buf-
fer Error (Eth-
erCAT)
88080000 hex
PLC Link
Communica-
tions Error
EtherCAT FQ-M-series Specialized Vision Sensors for Positioning
The manual names are given below for the catalog numbers given in the Reference column of the
event table.
Cat. No.
Z314
Event code
Event name
78080000 hex
TRIG Input
Error
780A0000 hex
Scene Data
Error
780B0000 hex
Model Error
780C0000 hex
Logging Error Some data was not
780D0000 hex
Output Time-
out
780E0000 hex
Output Size
Error
NJ/NX-series Troubleshooting Manual (W503)
Meaning
Assumed cause
An error occurred
• Scene data was edited when
while transferring
there was little available space
the scene data.
on the RAM disk and the opera-
tion mode was Double Speed
Multiinput.
• The data transfer button was
clicked when there was little
available space on the RAM
disk and the operation mode
was Non-stop Adjustment
Mode.
The data output
• Data measurements are being
buffer for measure-
performed on a period that is
ment data is full.
shorter than the time that is
required for data output hand-
shake controls in the program.
A PLC Link cannot
• There is a mistake in the PLC
be established.
or Vision Sensor communica-
tions settings.
• The Ethernet or RS-232C cable
is damaged.
FQ-M-series Specialized Vision Sensor for Positioning User's Manual
Meaning
Assumed cause
A TRIG signal was
• A TRIG signal was input when
input when the
the BUSY signal for Sensor
BUSY signal for
measurement was ON.
Sensor measure-
• Chattering occurred for a con-
ment was ON.
tact input.
The scene data to
• The power supply was inter-
switch to is cor-
rupted when the scene data to
rupted.
switch to was saved.
A model was re-
• A model was re-registered with
registered with an
an image with low contrast.
image with low con-
trast.
• Too much data to log in files
saved when logging
occurred in a short period of
data to files on an
time, and writing to the SD card
SD card.
could not keep up.
A timeout occurred
• The data output handshaking
in data output hand-
controls in the program (i.e., the
shaking control for
ON/OFF timing of the DSA sig-
measurement
nal) are not correct.
results.
• The output control timeout time
is too short in comparison with
the program processing time.
The data output
• The EtherCAT data output size
size setting and the
setting in the Sensor and the
PDO mapping set-
PDO mapping setting in the
ting do not agree.
EtherCAT master do not agree.
Level
Maj
Prt
Min
Obs Info
S
S
S
Manual name
Level
Maj
Prt
Min
Obs Info
S
S
S
S
S
S
3 Error Tables
Reference
Z342
Z342
3
Z342
Reference
Z314
Z314
Z314
Z314
Z314
Z314
3-219

Advertisement

Table of Contents
loading

Table of Contents