Event code
Event name
67980000 hex
Cycle Start
Specified
during Nega-
tive Limit
Input
67990000 hex
NC Program
Execution
Error
77820000 hex
CNC Coordi-
nate System
Composition
CNC Motor
Error
77830000 hex
CNC Com-
mon Error
Occurrence
77840000 hex
Servo Main
Circuits OFF
77850000 hex
Servo Main
Circuit Power
OFF
77860000 hex
Slave Error
Detected
77880000 hex
Slave Dis-
connection
during Servo
ON
77890000 hex
Homing
Opposite
Direction
Limit Input
Detected
NJ/NX-series Troubleshooting Manual (W503)
Meaning
Assumed cause
A cycle start was
• A cycle start was executed
executed when the
when the negative limit input
negative limit input
was ON.
was ON.
An error was
• An error was detected while the
detected while the
NC program is running.
NC program is run-
Refer to error codes in the fol-
ning.
lowing attached information for
details on errors.
An error occurred
• An error occurred for a compo-
for a composition
sition CNC motor in a CNC
CNC motor in a
coordinate system while it is
CNC coordinate
moving.
system.
A CNC common
• Partial fault level CNC common
error occurred.
error occurred.
An attempt was
• An attempt was made to turn
made to turn ON
ON the Servo when the main
the Servo when the
circuit power supply to the
main circuit power
Servo Drive was OFF.
supply to the Servo
Drive was OFF.
The main circuit
• The main circuit power of the
power of the Servo
Servo Drive was interrupted
Drive turned OFF
while the Servo was ON.
while the Servo was
ON.
An error was
• An error was detected for the
detected for the
EtherCAT slave or NX Unit that
EtherCAT slave or
is allocated to the CNC motor.
NX Unit that is allo-
cated to the CNC
motor.
An EtherCAT slave
• An EtherCAT slave or NX Unit
or NX Unit that is
that is allocated to the CNC
allocated to the
motor was disconnected,
CNC motor was
replaced, or disabled while the
disconnected,
Servo was ON.
replaced, or dis-
abled while the
Servo was ON.
The limit signal in
• The Operation Selection at
the direction oppo-
Negative Limit Input or Opera-
site to the homing
tion Selection at Positive Limit
direction was
Input parameter is set to No
detected during a
reverse turn.
homing operation.
• The location of the homing
input signal sensors, homing
settings, and homing start posi-
tion cause a limit input to be
reached.
• The input signal sensor wiring
is incorrect or the sensor is
faulty.
3 Error Tables