Omron NX701-17 Series Troubleshooting Manual page 118

Machine automation controller nj/nx-series
Hide thumbs Also See for NX701-17 Series:
Table of Contents

Advertisement

3 Error Tables
Event code
Event name
54014805 hex
Communications
Timeout
(Ver. 1.12 or
later)
54014806 hex
Invalid Mode
(Ver. 1.12 or
later)
54014807 hex
I/O Power OFF
Status
(Ver. 1.12 or
later)
54014808 hex
Verification Error
(Ver. 1.12 or
later)
54015420 hex
Electronic Gear
Ratio Numerator
Setting Out of
Range
54015421 hex
Electronic Gear
Ratio Denomina-
tor Setting Out of
Range
54015422 hex
Target Velocity
Setting Out of
Range
54015423 hex
Acceleration Set-
ting Out of Range
54015424 hex
Deceleration Set-
ting Out of Range
54015425 hex
Jerk Setting Out of
Range
54015427 hex
Torque Ramp Set-
ting Out of Range
54015428 hex
Master Coefficient
Scaling Out of
Range
54015429 hex
Slave Coefficient
Scaling Out of
Range
5401542A hex
Feeding Velocity
Setting Out of
Range
3-40
Meaning
A timeout occurred in com-
• The communications
munications.
• The cable for Ether-
• Noise
• Device failure
The specified IO-Link mas-
• The specified IO-Link
ter port is not the IO-Link
mode.
The I/O power is not sup-
• The I/O power is not
plied to the specified IO-
Link master port.
The specified IO-Link mas-
• The specified IO-Link
ter port had a verification
error or a communications
error.
The parameter specified for
• Instruction input
the RatioNumerator input
variable to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the RatioDenominator input
variable to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the Velocity input variable
to a motion control instruc-
tion is out of range.
The parameter specified for
• Instruction input
the Acceleration input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the Deceleration input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the Jerk input variable to a
motion control instruction is
out of range.
The parameter specified for
• Instruction input
the TorqueRamp input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the MasterScaling input
variable to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the SlaveScaling input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• The Feed Velocity
the FeedVelocity input vari-
able to a motion control
instruction is out of range.
Assumed cause
Maj
Prt
timeout time is shorter
than the message
response time.
CAT or for IO-Link is
broken.
master port is not the
IO-Link mode.
supplied to the speci-
fied IO-Link master
port.
master port had a veri-
fication error or a com-
munications error.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
(input variable Feed-
Velocity) is still at the
default (0).
NJ/NX-series Troubleshooting Manual (W503)
Level
Refer-
ence
Min
Obs
Info
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502

Advertisement