Event code
Event name
547E0000 hex
Circular Inter-
polation Set-
ting Out of
Range
547F 0000 hex
Auxil-
iary/Slave
Axis Num-
bers Not in
Ascending
Order
54800000 hex
Cam Table
Property
Ascending
Data Error at
Update
54810000 hex
MC_Write
Target Out of
Range
54820000 hex
Master Travel
Distance
Specification
Out of Range
54830000 hex
Master Dis-
tance in
Acceleration
Specification
Out of Range
54840000 hex
Master Dis-
tance in
Deceleration
Specification
Out of Range
54870000 hex
Execution
Mode Selec-
tion Out of
Range
NJ/NX-series Troubleshooting Manual (W503)
Meaning
Assumed cause
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
CircAxes input vari-
input variable.
able to a motion
• The axes that were specified in
control instruction is
CircAxes are not included in the
out of range.
composition axes in the Axes
Group Settings.
• The same axis was specified
for both axes of CircAxes.
The values of the
• The parameters for the Auxil-
parameters for the
iary and Slave input variables
Auxiliary and Slave
to the instruction are not in
input variables to a
ascending order.
motion control
instruction are not
in ascending order.
A phase that was
• A phase that was not in
not in ascending
ascending order was found
order was found
when calculating the number of
during calculating
valid data.
the number of valid
• After calculations, the number
data. Or, after cal-
of valid data is 0.
culations, the num-
ber of valid data is
0.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
Target input vari-
input variable.
able to a motion
control instruction is
out of range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
MasterDistance
input variable.
input variable to a
motion control
instruction is out of
range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
MasterDistance-
input variable.
ACC input variable
to a motion control
instruction is out of
range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
MasterDistance-
input variable.
DEC input variable
to a motion control
instruction is out of
range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
ExecutionMode
input variable.
input variable to a
motion control
instruction is out of
range.
3 Error Tables
Level
Maj
Prt
Min
Obs Info
S
W508
S
W508
S
W508
S
W508
S
W508
S
W508
S
W508
S
W508
Reference
3