Key Points for Test Measurement and Adjustment (Control Flow Fieldbus)

You can adjust the parameters while you perform test measurements and check the measurement results to
increase the measurement precision and speed.
Select the adjustment method by considering the following point.
For the display of measurement results and the results that are output, check Reference: Measurement
Results for Which Output Is Possible (Control Flow Fieldbus) (p.860).
Items Displayed in the Detail Result Area
The following measurement results are displayed in the "Detail result" area as text.
Displayed item
Judge
Items Displayed in the Image Display Area
You can specify a sub-image number to display the next image in the image display area.
Sub image number
0

Measurement Results for Which Output Is Possible (Control Flow Fieldbus)

The measurement results provided by control flow parallel are shown below. The measurement results appear in
the "Detail Result" area, and you can also use result output processing items to output the measurement results
to an external device.
Refer to the "External Reference Tables" for the parameters that can be referenced, including measurement
results.
(Reference: External Reference Table (Control Flow Fieldbus) (p.860))
Measurement item
Judge

External Reference Table (Control Flow Fieldbus)

By specifying a number, you can access the following data from processing items that support processing unit
data setting/acquisition, and from control commands.
No.
0
Judge
5
State
103
Reflect to the overall judgement
120
Timeout
121
Timeout time (ms)
122
Communication method
860
Control Flow Fieldbus
Displays the judgement result for the processing unit.
The measurement image appears.
Character string
JG
The judgement result for the processing unit
Data name
Get only
Get only
Set/Get
Set/Get
Set/Get
Set/Get
Description
Description
Description
Set/Get
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
0: Flow not stopped
1: Flow stopped
0: ON
1: OFF
0: Not used
1: Used
Timeout time (0 to 120,000)
0: EtherNet/IP
1: EtherCAT
FH/FZ5 Processing Item Function Reference Manual