If you select [GS1 DataBar] or [GS1-128] for the code type, set a group separator replacement
condition.
Setting item
Replace group
separator with specified
character string
Replacement character
string
Note
Replacing each group separator (control character) with the specified character string enables codes containing
group separators to be read and compared to a comparison character string.
7
When the setting has been changed,
click [Measurement] in the "Detail" area
to verify whether measurements can be
made correctly.
8
Set up the judgement condition.
Setting item
Character count
Verification string
'*' '?' is treated as
character data.
Integrated quality
FH/FZ5 Processing Item Function Reference Manual
Set value
[Factory default]
If you select [GS1-128] or [GS1 DataBar] for the code type, check this
• [Checked]
checkbox to replace each group separator with another character
• Unchecked
string.
---
Set the character string to replace group separators with.
Set value
0 to 1024
Specify the character count to be judged as OK.
[1024]
Up to 1023
Specify the character strings to be judged as OK.
characters can be set.
Checked: '*' and '?' are handled as normal characters.
• Checked
Unchecked: '*' and '?' are handled as special characters.
• [Unchecked]
'*': Substitution for character string (with 0 or more characters)
'?': Substitution for 1character
0 to 4
Specify the integrated quality to be judged as OK.
[4]
Description