Omron FH-3 Series Reference Manual page 277

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

3
If necessary, set each item in the "Noise
removal" area.
Setting item
Noise level
Noise width
Filter strength
4
In the "Sub-region detail" area, set
enable or disable measurement as
required.
Setting item
Check No. range
FH/FZ5 Processing Item Function Reference Manual
Set value
[Factory default]
• For color cameras
3 to 442 [5]
When detection is affected by noise, increase this value.
• For monochrome
Reference:
cameras
the "Vision System FH/FZ5 Series User's Manual (Z365)"
0 to 255 [5]
Set the width for judging noise.
0 to 9999
When detection is affected by noise, increase this value.
[0]
Reference:
the "Vision System FH/FZ5 Series User's Manual (Z365)"
If a valley appears in the histogram around the edge threshold value due
0 to 100
to noises, smoothen the edge profile using a filter to prevent wrong error
[0]
detection from being detected.
Strengthening the filter smoothen the edge profile further.
Set value
[Factory default]
Specify the edge measurement number for which to perform batch
0 to 359
reversing of the enable or disable measurement setting.
[0] to [359]
Click [Check reverse] to reverse the check box settings of the edge
measurement number within the range.
Description
"Appendixes Measurement Mechanism Noise Level" in
"Appendixes Measurement Mechanism Noise Width" in
Description
Circular Scan Edge Position
2
275