Machine Setting (Plc Master Calibration); Calibration (Plc Master Calibration) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Machine Setting (PLC Master Calibration)

Select a processing item (stage data or robot data) under which external device information needed for
calculation of axis movement amount is held.
Important
• [PLC Master Calibration] refers to [Stage Data] or [Robot Data]. Be sure to register [Stage Data] or [Robot Data] with a
given scene.
1
In the Item Tab area, click [Machine setting].
2
Select the processing unit that retains
information on external device.
Information of the selected processing unit is
displayed in the reference data display area.
Displayed contents may change depending on
selected type of Robot or Stage.
Setting item
Scene No.
Unit No.
Note
• If the number of scenes is increased using the scene group conversion tool, the maximum value that can be
selected in "Scene No." changes.

Calibration (PLC Master Calibration)

This item sets data related to calibration. Sets the number of calibration data to be created and the measurement
processing items to be used for sampling in the arithmetic expression. Also sets the output method for the
calculated axis movement amount.
1
In the Item Tab area, click [Calibration].
2
Select the calibration method in the
"Calibration type" area.
Setting item
Calibration type
FH/FZ5 Processing Item Function Reference Manual
Setting value
[Factory default]
Select a scene number (stage data or robot data) under which external
[Present scene]
device information needed for calculation of axis movement amount is
Scenes 0 to 127
held.
From among the referenced scene numbers, select a processing item
---
(stage data or robot data) under which external device information
needed for calculation of axis movement amount is held.
Setting value
[Factory default]
Perform calibration by combining the "measurement command" and "set
[Normal]
unit data command" from the control equipment (PLC).
Easy
Perform calibration by using the "measurement command" only.
Description
Description
PLC Master Calibration
4
769

Hide quick links:

Advertisement

Table of Contents
loading