Image Logging

This is used when saving measurement images to on-board memory, RAMDisk or USB memory.
This enables preparation of logging conditions using an expression and is more flexible than the system image
logging conditions settings.
However, the settings of this unit are enabled if "None" is set on the [Image logging] in [Logging setting] of
[System] menu.
Reference: "Chapter 3 Logging Measurement Values and Measurement Images instruction" in the Vision
Sensor FH/FZ5 Series Vision System User's Manual (Z365).
If settings that perform image logging for multiple units during measurement are executed, the last settings
executed are enabled.
Used in the Following Case
• This is used when saving logging images under specific conditions.
PC
Important
• If several image logging units are set in the flow, saving is performed based on the last image logging conditions
executed.
• When [Multiple image logging] in [Logging setting] of [System] is [ON], refer to the followings.
• All of the transfered images will be saved according to [Image logging] setting.
• Latest images that exceed Sensor Controller memory size will be deleted because all of the transfered images will be
saved temporarily.
• When [Save to memory + FTP Server] is selected for destination, specify the destination folder name and prefix of the
image logging file using only single-byte alphanumeric characters and numbers.