Setting Pattern Enable/Disable
For each character type, enable the patterns that you want to use for OCR and disable the patterns that you do
not want to use.
1
In the Item Tab area, click [Dictionary Reference].
2
Select the character type from the list in the registered characters list area.
3
Set the items in the registered characters list area.
Setting item
Pattern enable/disable
Character Code
Note
• Up to 10 patterns can be used for each character type.
Changing a Character Code Registered in a Pattern
A character code registered in one of the multiple patterns in each character type can be changed to a different
character code.
1
Select the character type from the list in the registered characters list area.
2
Select the pattern that you want to change from the pattern list.
3
Select the character code in [Character Code].
The character code of the character pattern selected in the list is changed.
Setting Character Type Enable/Disable
Enable character types that you want to use for OCR and disable character types that you do not want to use.
4
Select the character type from the list in the registered characters list area.
5
Click [Chara. Disable].
The character type selected in the list is disabled. To enable the character type, click [Chara. Enable].
Deleting a Character Type
You can delete a character type that has been registered in the dictionary.
1
Select the character type from the list in the registered characters list area.
2
Click [Chara. Delete].
The character type selected in the list is deleted.
FH/FZ5 Processing Item Function Reference Manual
Setting value
[Factory default]
• [ON]
If you do not want to use a pattern for OCR, remove the
• OFF
checkmark from "Pattern".
0 to 9, A to Z, :/)(
Set the character code of the character type.
Description