Trend Monitor - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Trend Monitor

Enables the history of the measurement results to be displayed on the monitor.
Used in the Following Case
• When you want to prevent repeated occurrences of failed product
450.000
400.000
350.000
By setting up the Warning range, "Warning" message can be
displayed to safeguard against frequent NG message, which
will then be fed back to the preceding process.
• When you want to analyze the cause of NG
450.000
350.000
Displays the measured value vs time characteristic.
List of Trend Monitor Items
Item name
Select the measurement value to be displayed on the trend monitor.
Measurement
Reference: Measurement Value (Trend Monitor) (p.663)
Specify the display range. You can scroll the display range of a graph up and down or zoom in/out.
Display range
Reference: Display Range (Trend Monitor) (p.664)
Set the conditions for deciding when measurement results are judged as OK, and set the warning range
Judgement
for issuing a caution before there are many NG occurrences.
Reference: Judgement (Trend Monitor) (p.666)
Display measurement history.
History display
Reference: Measurement History Display (Trend Monitor) (p.667)
Save the measurement results recorded in the trend monitor to the external memory device, i.e. USB memory.
Data save
Reference: Data Save (Trend Monitor) (p.669)
662

Trend Monitor

400.000
Judgement upper limit
Limits of warning
(upper limit)
Limits of warning
(lower limit)
Judgement lower limit
Description
FH/FZ5 Processing Item Function Reference Manual