Omron FH-3 Series Reference Manual page 124

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Setting item
Sub-model
number X
Sub-model
number Y
Stab.
Prec.
Plain
inspection
Disabled setting
You can specify enable/disable of each sub-region.
1
Click the region you wish to
disable and select "Disabled".
To release the disabling of a region,
click "Enable All".
Displaying/Re-Registering/Deleting a Model
If you save the model registration image, it is easy to
re-register the model after model parameters are
changed.
Item
Disp model/Input image
Re-register
Delete
122
Sensitive Search
Set value
[Factory default]
0 to 10
This sets the number of divisions of the registered model in the X direction.
[4]
0 to 10
This sets the number of divisions of the registered model in the Y direction.
[4]
1 to 15
Specify which is to have priority, measurement stability or speed.
[The default value
If lowering stability does not speed up processing, it is likely that many
depend on the
candidates have been detected. In this case, specify a larger value for
connected camera.
"Candidate level" or "Stab."
12 or 15]
1 to 3
Specify which is to have priority, measurement positional precision or speed.
[2]
• Checked
Specify whether or not to inspect the plain region.
• [Unchecked]
The model image display and input image display are switched.
When model parameters are modified, display the original model image and re-register the
model.
Deletes a model.
Description
Divided model regions
Description
FH/FZ5 Processing Item Function Reference Manual
←Set as invalid

Hide quick links:

Advertisement

Table of Contents
loading