Omron FH-3 Series Reference Manual page 822

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

If "Length" is selected for [Dimension measure].
Setting item
Width unit No.
If "2 points" is selected for [Dimension measure].
Setting item
Point 1 and 2 unit
No.
If "Specify point" is selected for [Origin].
Setting item
Camera X and Y
Changed X and Y
3
Click [Region] as needed to set sampling measurement conditions.
4
Click [Sampling measurement].
5
Click [Generate calibration parameters].
The calibration parameters will be generated.
9 Changes display settings as needed.
Setting item
Display setting
820
Camera Calibration
Setting value
[Factory default]
• Width reference unit in the
measurement flow
• [<None>]
Setting value
[Factory default]
• Point width measurement unit in the
measurement flow
• [<None>]
Setting value
[Factory default]
-99999.9999 to 99999.9999
[0]
-99999.9999 to 99999.9999
[0]
Setting value
[Factory default]
• [Input image]
• X unit image
• Y unit image
Select the scan edge width processing unit in the
current scene.
Select the processing unit that can perform point
measurement in the current scene.
Set the camera coordinates for a given point.
If the origin of the actual coordinates is included in
the field of view, measure the origin position of the
actual coordinates in advance and set them to the
camera coordinates X and Y.
Set the actual coordinate values set as the camera
coordinates.
If the origin position of the actual coordinates is set
as the camera coordinates, set (0.0, 0.0).
Explanation
Select the type of image to display in the Image display area.
The display setting is valid only in the sampling tab screen.
FH/FZ5 Processing Item Function Reference Manual
Description
Description
Description