Measurement Results For Which Output Is Possible (Elapsed Time); External Reference Tables (Elapsed Time) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Note
• Time elapse can be confirmed on the main screen "Detail result" area.

Measurement Results for Which Output Is Possible (Elapsed Time)

The following values can be output using processing items related to results output. It is also possible to
reference measurement values from expressions and other processing units.
Measurement items
Judge
Elapsed Time

External Reference Tables (Elapsed Time)

No.
0
Judge
5
Elapsed Time
690
Elapsed Time
Character string
JG
Latest processing unit judgement result
TM
Elapsed time from start of measurement (ms)
Data name
Set/Get
Get only
Get only
Description
Data range
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
0 to 999999