Value Appointment (Camera Calibration)

Set the magnification ratio as a numeric value to make the calibration setting.
1
In the Item Tab area, click [Value appointment].
2
Set the [Value appointment] area.
Setting item
Coordinate
Origin
Magnification
If "Specify point" is selected for [Origin].
Setting item
Camera X and Y
Changed X and Y
816
Camera Calibration
Setting value
[Factory default]
• [Lefthand]
• Righthand
• [Upperleft]
• Lowerleft
• Center
• Specify point
0.0001 to 9.9999
[1.0000]
Setting value
[Factory default]
-99999.9999 to 99999.9999
[0]
-99999.9999 to 99999.9999
[0]
Description
Lefthand: Clockwise is forward when
specifying the coordinates.
Righthand: Counter-clockwise is
forward when specifying the
coordinates.
Select where the origin of the
actual coordinates will be.
Specify the ratio of 1 pixel to the actual dimensions.
Set the camera coordinates for a given point.
If the origin of the actual coordinates is included in
the field of view, measure the origin position of the
actual coordinates in advance and set them to the
camera coordinates X and Y.
Set the actual coordinate values set as the camera
coordinates.
If the origin position of the actual coordinates is set
as the camera coordinates, set (0.0, 0.0).
FH/FZ5 Processing Item Function Reference Manual
Left-hand
type
0
X
Forward
Y
Y
Right-hand
Forward
type
0
X
Upperleft
Center
Lowerleft
Description