Angle calculation
method selection
Point 0
Point 1
Point 2
Point 3
Side line formed by
Points 0-1
Side line formed by
Points 0-2
Side line formed by
Points 0-3
Side line formed by
Points 1-0
Side line formed by
Points 1-2
Side line formed by
Points 1-3
Side line formed by
Points 2-0
Side line formed by
Points 2-1
Side line formed by
Points 2-3
Side line formed by
Points 3-0
Side line formed by
Points 3-1
Side line formed by
Points 3-2
4
Set the position information of Points 0 to 3 as needed.
5
If the setting has been changed, click
[Measure] to check the calculation
result.
6
Set up the judgement condition.
Setting item
Calculate position X
Calculate position Y
Calculate angle
FH/FZ5 Processing Item Function Reference Manual
Data necessary for angle data (: data needed to be entered)
Point 0
Position
Position
Angle
XY
XY
Setting value
[Factory default]
-99999.9999 to 99999.9999
-99999.9999 to 99999.9999
-180.0000 to 180.0000
Point 1
Point 2
Position
Angle
XY
Description
Specify the range of X-axis calculation positions that is
judged to be OK.
Specify the range of Y-axis calculation positions that is
judged to be OK.
Specify the range of calculation angles that is judged to
be OK.
Point 3
Position
Angle
Angle
XY
Position Data Calculation