Settings Flow (Vision Master Calibration)

Set the image master calibration with the following steps.
Make sure to set
Start
Machine Setting
(Vision Master Calibration)
Calibration
(Vision Master Calibration)
Sampling Setting
(Vision Master Calibration)
Settings complete
Test measurement
List of Vision Master Calibration Items
Item name
Select a processing item (stage data or robot data) under which external device information needed for
Machine setting
calculation of axis movement amount is held.
Reference: Machine Setting (Vision Master Calibration) (p.746)
This item sets data related to calibration. Sets the number of calibration data to be created and the
measurement processing items to be used for sampling in the arithmetic expression. Also sets the
Calibration
output method for the calculated axis movement amount.
Reference: Calibration (Vision Master Calibration) (p.746)
This item sets data related to sampling.
Sampling setting
Also makes the sampling settings for the initial calibration and this calibration.
Reference: Sampling Setting (Vision Master Calibration) (p.750)
This item confirms the calibration data you created. The calibration data can be adjusted directly using
the Edit function.
Calibration result
It is also possible to confirm the sampling data used for the calculation.
Reference: Calibration Result (Vision Master Calibration) (p.756)
FH/FZ5 Processing Item Function Reference Manual
Set as necessary.
Calibration result
(Vision Master Calibration)
Check results/make adjustments
Description
Vision Master Calibration
4
745