No.
1001 + N × 10
Y-direction movement of parallel position
(N: 0 to 99)
No.N
2000 + N × 10
X-direction movement of rotation position
(N: 0 to 99)
No.N
2001 + N × 10
Y-direction movement of rotation position
(N: 0 to 99)
No.N
2002 + N × 10
TH-direction movement of rotation
(N: 0 to 99)
position No.N
5000
Calibration start/end
5001
Set calibration target
5002 *1
Set standard position
5003
Set parallel position
5004
Set rotation position
5005 *1
Calculate calibration data
5006 *1
Calculate deflection data
5007 *1
Clear sampling data
5009 *1
Clear step counter
14000 + N × 10000
Deflection of dataN
(N: 0 to 7)
14001 + N × 10000
Calibration parameter A of dataN
(N: 0 to 7)
14002 + N × 10000
Calibration parameter B of dataN
(N: 0 to 7)
14003 + N × 10000
Calibration parameter C of dataN
(N: 0 to 7)
14004 + N × 10000
Calibration parameter D of dataN
(N: 0 to 7)
14005 + N × 10000
Calibration parameter E of dataN
(N: 0 to 7)
14006 + N × 10000
Calibration parameter F of dataN
(N: 0 to 7)
14007 + N × 10000
X magnification of dataN
(N: 0 to 7)
14008 + N × 10000
Y magnification of dataN
(N: 0 to 7)
14009 + N × 10000
Origin X of dataN
(N: 0 to 7)
14010 + N × 10000
Origin Y of dataN
(N: 0 to 7)
14011 + N × 10000
X-axis angle of dataN
(N: 0 to 7)
14012 + N × 10000
Y-axis angle of dataN
(N: 0 to 7)
14013 + N × 10000
XY-axis angle of dataN
(N: 0 to 7)
*1:
If you set the external reference table and execute the applicable Processing unit item, confirm the current Processing unit item
is same as the selected Scene.
FH/FZ5 Processing Item Function Reference Manual
Data name
Set/Get
Set/Get
Set/Get
Set/Get
Set only
Set only
Set only
Set only
Set only
Set only
Set only
Set only
Set only
Get only
Set/Get
Set/Get
Set/Get
Set/Get
Set/Get
Set/Get
Get only
Get only
Get only
Get only
Get only
Get only
Get only
Set/Get
Data range
-999,999,999.9999 to 999,999,999.9999
-999,999,999.9999 to 999,999,999.9999
-999,999,999.9999 to 999,999,999.9999
-180.0000 to 180.0000
0: Calibration end
1: Calibration start
0 to 255
1 to 1
1 to 100
1 to 100
1: Execute
1: Execute
1: Clear
1: Clear
---
-999,999,999.9999 to 999,999,999.9999
-999,999,999.9999 to 999,999,999.9999
-999,999,999.9999 to 999,999,999.9999
-999,999,999.9999 to 999,999,999.9999
-999,999,999.9999 to 999,999,999.9999
-999,999,999.9999 to 999,999,999.9999
---
---
---
---
---
---
---
775
PLC Master Calibration
4

Hide quick links: