Omron FH-3 Series Reference Manual page 759

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Setting item
Display
Display
setting
setting
Data No.
Item
First calibration data
Precise calibration data
A to F
X magnification
Y magnification
X-axis angle
Y-axis angle
Origin X
Origin Y
XY-axis angle
Error evolution
X max error
Y max error
Sampling data list
[Clear step counter] button
FH/FZ5 Processing Item Function Reference Manual
Setting value
[Factory default]
0 to 7
[0]
Displays details of the first calibration parameter.
Displays details of the calibration data.
Displays details about the calibration parameters.
Clicking [Edit enable] will let you change the numbers for A to F.
If any number has been changed, the message "This data has been edited" appears
at the left of [Edit enable].
This magnification is the coordinates of X axis direction after calibration.
This magnification is the coordinates of Y axis direction after calibration.
This angle is camera coordinate of X-axis and the coordinates of X axis direction
after calibration.
This angle is camera coordinate of Y-axis and the coordinates of X axis direction
after calibration.
This is an origin X after calibration.
This is an origin Y after calibration.
This is XY-axis angle after calibration.
Maximum value of distance calculated standard position and sampling result.
Stage is not set to θaxis, [-] is displayed because calculation is impossible.
Maximum error of X-axis coordinate position calculated standard position and
sampling result.
Stage is not set to X axis, [-] is displayed because calculation is impossible.
Maximum error of Y-axis coordinate position calculated standard position and
sampling result.
Stage is not set to X axis, [-] is displayed because calculation is impossible.
Displays sampling data used for creating the calibration parameters.
Reference position displays the movement amount from the origin return position (all
axes at 0.0 position).
Data other than the reference position displays the movement amount from the
reference position when [One by one] is selected as the sampling method.
Reference position is re-set befer this calibraiton is executed.
Normally, non-existenting axis avlue is 0 when Xθ, Yθ, θX, θY, X or Y stage is
selected.
Set back the reference position as the next measurement target and start over
calibrations
Description
Sets the calibration data number that displayed the
calculation results.
Description
Vision Master Calibration
4
757