Omron FH-3 Series Reference Manual page 572

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Setting Items for 2 Images Operation Filter
Setting item
Target image 2
Unit image 2
Unit image number
2
Filtered image 2
Operation type
Operation mode
Bit operation mode
Note
The Output coordinates (Before/Afer scroll and Calibration ON/OF) of the measurement unit for the image after
performing 2 images operation are calculated with the image selected in "Target"of 2 images operation.
570
Advanced Filter
Setting value
[Factory default]
• Measurement
This can be set when "2 images operation filter" is selected in "Filter
image
Setting".
• [Pre filter image]
As target image 2, set the image that is used with the target image in the
• Other unit image
operation.
• Filtered image
The setting values that can be selected are the same as for "Target".
This can be set when "Filter Setting" is "2 images operation filter" and
"Processing unit image" is selected for "Target image 2".
• [None]
Set the processing unit that holds the image used as target image 2. A
• 0 to 9,999
processing unit of an image input processing item or image conversion
processing item can be selected. If the selected processing unit does not
hold an image, invalid image occurs and a black image is displayed.
This can be set when "Filter Setting" is "2 images operation filter" and
"Processing unit image" is selected for "Target image 2".
0 to 3 [0]
Set the image number of the image that is used as target image 2. If the
processing unit does not hold the image of the set image number, invalid
image occurs and a black image is displayed.
This can be set when "Filter Setting" is "2 images operation filter" and
"Filtered image" is selected for "Target image 2".
• [None]
Set the processing unit that holds the image used as target image 2. A
• 0 to 14
processing unit that performed processing prior to the current processing
unit can be selected.
• [Operation]
Select the type of operation for 2 "Images Operation Filter".
• Bit operation
• [Add]
• Subtraction
• Subtraction
(Absolute)
This setting becomes valid if "Operation" is selected for "Operation type".
• Multiplication
The pixel values of two images are calculated in Operation mode and the
• Multiplication
result is used as the pixel values after conversion.
(Normalization)
• Average
• Maximum
• Minimum
• [AND]
• OR
This setting becomes valid if "Bit operation" is selected for "Operation
• XOR
type".
• NAND
The pixel values of two images are calculated in Bit operation mode and
• NOR
the result is used as the pixel values after conversion.
• XNOR
Description
FH/FZ5 Processing Item Function Reference Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents