Key Points for Test Measurement and Adjustment (Control Flow PLC Link)

You can adjust the parameters while you perform test measurements and check the measurement results to
increase the measurement precision and speed.
Select the adjustment method by considering the following point.
For the display of measurement results and the results that are output, check Reference: Measurement
Results for Which Output Is Possible (Control Flow PLC Link) (p.849).
Items Displayed in the Detail Result Area
The following measurement results are displayed in the "Detail result" area as text.
Displayed item
Judge
Items Displayed in the Image Display Area
You can specify a sub-image number to display the next image in the image display area.
Sub image number
0

Measurement Results for Which Output Is Possible (Control Flow PLC Link)

The measurement results provided by control flow PLC link are shown below. The measurement results appear
in the "Detail Result" area, and you can also use result output processing items to output the measurement
results to an external device.
Refer to the "External Reference Tables" for the parameters that can be referenced, including measurement
results.
(Reference: External Reference Table (Control Flow PLC Link) (p.849))
Measurement item
Judge

External Reference Table (Control Flow PLC Link)

By specifying a number, you can access the following data from processing items that support processing unit
data setting/acquisition, and from control commands.
No.
Data name
0
Judge
5
State
103
Reflect to the overall judgement
120
Timeout
121
Timeout time (ms)
122
Communication method
FH/FZ5 Processing Item Function Reference Manual
Displays the judgement result for the processing unit.
The measurement image appears.
Character string
JG
The judgement result for the processing unit
Set/Get
Get only
Get only
Set/Get
Set/Get
Set/Get
Set/Get
Description
Description
Description
Data range
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
0: Flow not stopped
1: Flow stopped
0: ON
1: OFF
0: Not used
1: Used
Timeout time (0 to 120,000)
0: RS-232C/RS-422