Omron FH-3 Series Reference Manual page 468

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Setting item
Verification
limits 1
Verification
limits 2
Verification
limits 3
Verification
limits 4
Setting Judgement Conditions Individually by Character
Set judgement conditions for all characters individually by character.
1
In the judgement condition area, click [Detail setting].
The individual judgement condition area appears.
2
Set the items in the individual judgement condition area.
466
OCR
Setting value
[Factory default]
• [Unchecked]
• Checked
1 to 1024
[1] to [1024]
• [Unchecked]
• Checked
1 to 1024
[1] to [1024]
• [Unchecked]
• Checked
1 to 1024
[1] to [1024]
• [Unchecked]
• Checked
1 to 1024
[1] to [1024]
Description
The setting is enabled if [OCV] is specified for the inspection mode
and [Unit] is specified for the OCV condition.
Click on the [Verification limits 1] checkbox to turn it ON to verify
the character string on the first line.
The setting is enabled if [OCV] is specified for the inspection
mode, [Unit] is specified for the OCV condition, and the
[Verification limits 1] checkbox is checked.
Set the range for the character string that is to be used as the
character verification string on the first line of the measurement
results for the processing unit specified by the reference unit.
The setting is enabled if [OCV] is specified for the inspection mode
and [Unit] is specified for the OCV condition.
Click on the [Verification limits 2] checkbox to turn it ON to verify
the character string on the second line.
The setting is enabled if [OCV] is specified for the inspection
mode, [Unit] is specified for the OCV condition, and the
[Verification limits 2] checkbox is checked.
Set the range for the character string that is to be used as the
character verification string on the second line of the
measurement results for the processing unit specified by the
reference unit.
The setting is enabled if [OCV] is specified for the inspection mode
and [Unit] is specified for the OCV condition.
Click on the [Verification limits 3] checkbox to turn it ON to verify
the character string on the third line.
The setting is enabled if [OCV] is specified for the inspection
mode, [Unit] is specified for the OCV condition, and the
[Verification limits 3] checkbox is checked.
Set the range for the character string that is to be used as the
character verification string on the third line of the measurement
results for the processing unit specified by the reference unit.
The setting is enabled if [OCV] is specified for the inspection mode
and [Unit] is specified for the OCV condition.
Click on the [Verification limits 4] checkbox to turn it ON to verify
the character string on the fourth line.
The setting is enabled if [OCV] is specified for the inspection
mode, [Unit] is specified for the OCV condition, and the
[Verification limits 4] checkbox is checked.
Set the range for the character string that is to be used as the
character verification string on the fourth line of the measurement
results for the processing unit specified by the reference unit.
FH/FZ5 Processing Item Function Reference Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents