Omron FH-3 Series Reference Manual page 230

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

A reference position can be set either directly or by referencing a unit.
Specifying directly
Click a position on the image you want to use as a reference position, or set coordinate data for that point.
1
In the Item Tab area, click [Ref. setting].
In the display area, the current reference
position will be displayed as the crosshair
cursor.
2
In the "Method" area, select "Numerical".
3
Click the position to be set as the
reference.
Note
• Displaying the image enlarged makes this clicking easier.
Reference:
FH/FZ5 Series User's Manual (Z365)"
4
Make fine adjustments using numeric
value inputs or the arrow buttons as
required.
5
To remeasure on the displayed image
and set the reference, click the [Measure
ref.] button.
6
To use data before position
compensation for the reference setting
coordinates, place a check at "Use point
coordinate before scroll".
Referencing a unit
Set a reference by referencing a detection point unit with registered X coordinate, Y coordinate and angle data.
1
In the Item Tab area, click [Ref. setting].
In the display area, the current reference position will be displayed as the crosshair cursor.
2
In the "Method" area, select "Unit".
3
In the scene in the "Unit" area, select a
detection point unit.
4
Perform the next measurement, and the reference will be displayed.
228
Edge Position
"Appendixes Basic Knowledge about Operations Using the Zoom Function" in the "Vision System
FH/FZ5 Processing Item Function Reference Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents