Data Save (Trend Monitor) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Data Save (Trend Monitor)

The measurement results recorded in the trend monitor can be saved in a USB memory stick or SD card (for FH
series). Since the data is saved in CSV format, it can be edited on the PC.
The data to be saved includes all the statistical data, the value and time stamp when NG occurs (up to 36 items)
and the measurement result on the graph (up to 1000 items). Up to 100000 items of measurement results can
be saved in extended format. The format is as follows.
Data is partitioned using commas.
Important
• Insert a USB memory stick or SD memory card before saving data.
For information on the position of the USB connector and SD card memory, refer to
Hardware Setup Manual (Cat. No. Z366) or Instruction sheet.
1
In the Item Tab area, click [Data save].
2
Specify format in the "Save setting" area.
Standard format
Line
<Maximum>, <Minimum>, <Average>, <Deviation>,
1
<Count>, <NG count>, <Warning count>
2
3
0, <NG measured value, latest>, <Time>
4
1, <Last 1 NG measurement>, <Time>
5
2, <Last 2 NG measurement>, <Time>
:
:
38
35, <Last 35 NG measurement>, <Time>
39
40
0, <measured value, latest>
41
1, <Last 1 measurement>
42
2, <Last 2 measurement>
:
:
1039
999, <Last 999 measurement>
FH/FZ5 Processing Item Function Reference Manual
Latest NG error
1 NG error previous
2 NG errors previous
35 NG errors previous
Latest
1 previous
2 previous
999 previous
Text
Statistical data
Measurement
results during
NG errors
Graph
measurement
results
the Vision System FH/FZ5 series
Description
Statistical data
Last NG
Measurement
Last 1 NG
results when NG
Last 2 NG
occurs
:
(Max: 36 items)
Last 35 NG
Last
Last 1
Measurement result
Last 2
(Max: 1000 items)
:
Last 999
Trend Monitor
4
669

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents