[2] Continuous positioning control
[QD77MS4 operation example]
Address (+) direction
Address (-) direction
Positioning start signal
[Y10, Y11, Y12, Y13]
Start complete signal
[X10, X11, X12, X13]
BUSY signal
[XC, XD, XE, XF]
Positioning complete signal
[X14, X15, X16, X17]
(1) The machine always automatically decelerates each time the positioning is
completed. Acceleration is then carried out after the Simple Motion module
command speed reaches 0 to carry out the next positioning data operation.
If a dwell time is designated, the acceleration is carried out after the
designated time elapses.
(2) In operation by continuous positioning control (operation pattern "01"), the
next positioning No. is automatically executed. Always set operation pattern
"00" in the last positioning data to complete the positioning.
If the operation pattern is set to positioning continue ("01" or "11"), the
operation will continue until operation pattern "00" is found.
If the operation pattern "00" cannot be found, the operation may be carried
out until the positioning data No. 600. If the operation pattern of the
positioning data No. 600 is not completed, the operation will be started again
from the positioning data No. 1.
V
Positioning continue (01)
ON
OFF
ON
OFF
ON
OFF
OFF
Fig. 9.2 Operation during continuous positioning control
Chapter 9 Major Positioning Control
Positioning continue (01)
Dwell time
not designated
ON
(Note): Refer to Section 3.3 for input/output signal of QD77MS16.
9 - 7
Dwell
time
t
Positioning
complete (00)