Setting Range For The Op Shift Amount; Movement Speed During Op Shift - Mitsubishi Electric QD77MS User Manual

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

[2] Setting range for the OP shift amount

Set the OP shift amount within the range from the detected zero signal to the
upper/lower limit switches.
Setting range of the
negative OP
shift amount
Address decrease
direction
Lower limit switch
Zero signal
Fig. 13.5 Setting range for the OP shift amount

[3] Movement speed during OP shift

When using the OP shift function, the movement speed during the OP shift is set
in "[Pr.56] Speed designation during OP shift". The movement speed during the
OP shift is selected from either the "[Pr.46] OPR speed" or the "[Pr.47] Creep
speed". For the acceleration/deceleration time, the value specified in "[Pr.51]
OPR acceleration time selection" or "[Pr.52] OPR deceleration time selection"
is used.
The following drawings show the movement speed during the OP shift when a
mechanical OPR is carried out by the near-point dog method.
(1) OP shift operation at the "[Pr.46] OPR speed"
(When "[Pr.56] Speed designation during OP shift" is 0)
Pr. 44 OPR
V
direction
OP
Machine OPR start
Near-point dog
Zero signal
Fig. 13.6 OP shift operation at the OPR speed
Setting range of the positive OP shift amount
Address increase
direction
Near-point dog
Pr. 44 OPR direction
Pr. 46 OPR
speed
When the " Pr. 53 OP
shift amount" is negative
13 - 9
Chapter 13 Control Sub Functions
Upper limit switch
When the " Pr. 53 OP
shift amount" is positive
OP

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents