Classification
Warning
Warning name
of warnings
code
VCII series parameter
126
setting error
Outside mark detection
130
signal setting range
Outside mark detection
131
Common
data type setting range
warnings
Outside mark detection
132
data axis No. setting
range
Outside mark detection
133
data buffer memory No.
setting range
Speed change during
300
deceleration
JOG operation
warnings
301
JOG speed limit value
Manual pulse
Outside manual pulse
generator
401
generator input
operation
magnification range
warnings
Warning
The servo parameter "Absolute position
detection system (PA03)" is different from
VCII series.
The mark detection signal setting is
outside the range.
The mark detection data type setting is
outside the range.
When the mark detection data type setting
is not "Optional 2 word buffer memory",
the mark detection data type setting is
outside the range.
When the mark detection data type setting
is "Optional 2 word buffer memory", the
mark detection data buffer memory No. is
outside the range or odd number.
The speed change request is issued
during deceleration stop with JOG start
signal OFF.
(Note-1)
• The JOG speed
is exceeded the
speed limit value at start.
(Note-1)
• The new speed value
exceeds the
JOG speed limit value when the speed is
changed during operation.
(Note-1): This speed is a value in which
override value is considered
when override function is used.
("[Cd.13] Positioning operation
speed override" is set other than
100[%].)
The manual pulse generator 1 pulse input
magnification is set to 0, 10001 or more,
or negative value.
16 - 58
Chapter 16 Troubleshooting
Operation status at warning occurrence
The operation is executed by the setting of
VCII series.
All mark detections are not operated.
All mark detections are not operated.
The speed change is not carried out.
• When the speed exceeds the JOG speed
limit, the JOG operation is carried out with
the JOG speed limit value.
• While the speed is limited by the JOG
speed limit value, the "[Md.39] In speed
limit flag" is turned ON.
• When input magnification is set at 10001
or more, or negative value:
Re-set to 10000.
• When input magnification is set at 0: Re-
set to 1.