Mitsubishi Electric QD77MS User Manual page 924

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

Classification
Error
Error name
of errors
code
JOG acceleration time
957
selection setting error
JOG deceleration time
958
selection setting error
Acceleration/
959
deceleration process
selection setting error
S-curve ratio setting
960
error
Illegal sudden stop
961
deceleration time
Stop group 1 sudden
962
stop selection error
Stop group 2 sudden
963
stop selection error
Stop group 3 sudden
964
stop selection error
Outside allowance
Parameter
966
circular interpolation
setting range
error width
errors
External command
967
function selection error
Restart allowable range
970
error
Speed control 10 x
971
multiplier setting for
degree axis error
Number of master axis
972
error
973
Master axis No. error
Master axis setting
974
error
Driver communication
975
setting error
Error
The set value of the detailed parameter 2
"JOG operation acceleration time selection"
is outside the setting range.
The set value of the detailed parameter 2
"JOG operation deceleration time selection"
is outside the setting range.
The set value of the detailed parameter 2
"Acceleration/deceleration process
selection" is outside the setting range.
The set value of the detailed parameter 2
"S-curve ratio" is outside the setting range.
The set value of the detailed parameter 2
"Sudden stop deceleration time" is outside
the setting range.
The set value of the detailed parameter 2
"Stop group 1 sudden stop selection" is
outside the setting range.
The set value of the detailed parameter 2
"Stop group 2 sudden stop selection" is
outside the setting range.
The set value of the detailed parameter 2
"Stop group 3 sudden stop selection" is
outside the setting range.
The set value of the detailed parameter 2
"Allowance circular interpolation error
width" is outside the setting range.
The set value of the detailed parameter 2
"External command function selection" is
outside the setting range.
The set value of the detailed parameter 2
"Restart allowable range when servo OFF
to ON" is outside the setting range.
The set value of the detailed parameter 2
"Speed control 10 x multiplier setting for
degree axis" is outside the setting range.
Number of axes set for the master axis in
servo parameter "Driver communication
setting (PD15)" exceed the setting range.
Servo parameters "Driver communication
setting Master axis No. selection (1 to 4) for
slave (PD20 to PD23)" are set the self axis.
Not setting the master axis in Servo
parameters "Driver communication setting
Master axis No. selection (1 to 4) for slave
(PD20 to PD23) ".
• Setting the driver communication to servo
amplifier which does not support the
driver communication.
• The driver communication setting is
different in the module and the servo
amplifier.
16 - 44
Chapter 16 Troubleshooting
Operation status at error occurrence
When the PLC READY signal [Y0] is turned
from OFF to ON : The READY signal [X0] is
not turned ON.
At start
: The system does not
operate.
During operation : The system stops with the
setting (deceleration
stop/sudden stop) of the
detailed parameter 2
sudden stop selection
(stop group 3).
(Note that the deceleration
stop only occurs during the
manual pulse generator
operation.)
The READY signal [X0] is not turned ON.
The communication between servo amplifiers
of target axis is not executed.
(The servo amplifier's LED display remains
"Ab".)