Time Chart For Starting "Position-Speed Switching Control" - Mitsubishi Electric QD77MS User Manual

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

(5) Time chart for starting "position-speed switching control"

[QD77MS4 operation example]
Positioning start signal
All axis servo ON
Md. 26 Axis operation status
PLC READY signal
READY signal
Start complete signal
BUSY signal
Positioning complete signal
Error detection signal
Position-speed switching signal
Stop command
Fig. 6.8 Time chart for starting "position-speed switching control"
Chapter 6 Sequence Program Used for Positioning Control
Operation pattern (00)
V
Positioning data No. (1)
[Y10]
[Y1]
Servo OFF
Standby
[Y0]
[X0]
[X10]
[XC]
[X14]
[X8]
Cd. 3 Positioning start No.
Cd. 26 Position-speed
switching enable flag
6 - 63
Position control
1
1
(Note): Refer to Section 3.3 for input/output signal of QD77MS16.
Speed control
t
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents