Mitsubishi Electric QD77MS User Manual page 275

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

Reading the monitor value
Monitoring is carried out with a hexadecimal display.
0
0
0
b15
b12
b8
b4
Buffer
0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0
memory
Not
Not used
used
Monitor
8
value
b0
Stored items
b0
In speed control flag
b1
Speed-position switching latch flag
Command in-position flag
b2
b3
OPR request flag
b4
OPR complete flag
b5
Position-speed switching latch flag
b9
Axis warning detection
b10
Speed change 0 flag
b12
M code ON
b13
Error detection
QD77MS16
b14
Start complete
b15
Positioning complete
5 - 137
Chapter 5 Data Used for Positioning Control
Default
value
QD77MS2
QD77MS4
Default
Meaning
value
0008H
817+100n
0
0
0
1
0
0
0: OFF
1: ON
0
0
0
0
0
0
Buffer memory address
QD77MS16
2417+100n
n: Axis No.-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents