When the "JOG start signal" is turned ON again during deceleration caused
by the ON
When the "JOG start signal" is turned ON again during deceleration caused by the
ON
the time the "JOG start signal" is turned ON.
[QD77MS4 operation example]
Forward run JOG start
signal [Y8, YA, YC, YE]
BUSY signal
[XC, XD, XE, XF]
Fig. 11.9 Operation when the JOG start signal is turned ON during deceleration
When the "JOG start signal" is turned ON while the test function of
GX Works2 is used
When the "JOG start signal" is turned ON while the test function of GX Works2 is
used, it will be ignored and the JOG operation will not be carried out.
[QD77MS4 operation example]
In test mode flag
Forward run JOG start signal
[Y8, YA, YC, YE]
Fig. 11.10 Operation when the JOG start signal is turned ON while the test function is used
OFF of the "JOG start signal"
OFF of the "JOG start signal", the JOG operation will be carried out from
ON
OFF
ON
OFF
JOG operation not
JOG operation not possible
possible because
because this is not the
the test function is
rising edge of the JOG
being used
start signal
ON
ON
OFF
11 - 14
Forward run JOG operation
(Note): Refer to Section 3.3 for input/output signal of QD77MS16.
OFF
(Note): Refer to Section 3.3 for input/output signal of QD77MS16.
Chapter 11 Manual Control
t
Forward run JOG
operation execution
t