Set with a decimal.
Setting
K
value
Set with a decimal.
Setting
K
value
The Simple Motion module resets the value to "0" automatically
when processing of the step start request completes.
Set with a decimal.
Setting
K
1
value
The Simple Motion module resets the value to "0" automatically
when processing of the skip request completes.
Set with a decimal.
Setting
K
value
Set with a decimal.
Setting value
K
Setting value
Step valid flag
0: Invalidates step operations
1: Validates step operations
Step start information
1: Continues step operation
Skip request
1:
Issues a skip request to have
the machine decelerate, stop,
and then start the next positioning
operation.
Teaching data selection
0: Takes the current feed value as a positioning
address.
1: Takes the current feed value as an arc data.
5 - 183
Chapter 5 Data Used for Positioning Control
Default
value
0
0
0
0
0
Teaching
positioning
data No.
1 to 600
Buffer memory address
QD77MS2
QD77MS16
QD77MS4
1545+100n
4345+100n
1546+100n
4346+100n
1547+100n
4347+100n
1548+100n
4348+100n
1549+100n
4349+100n
n: Axis No.-1