Creating Start Programs For Jog Operation; Required Control Data Setting - Mitsubishi Electric QD77MS User Manual

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

11.2.4 Creating start programs for JOG operation

Setting item
Inching movement
[Cd.16]
amount
[Cd.17] JOG speed
: Refer to Section 5.7 "List of control data" for details on the setting details.
Signal name
PLC READY signal
READY signal
All axis servo ON
Synchronization flag
Interface
Axis stop signal
signal
Start complete signal
BUSY signal
Error detection signal
M code ON signal
Forced stop input signal
Stop signal
External
signal
Upper limit (FLS)
Lower limit (RLS)
A sequence program must be created to execute a JOG operation. Consider the
"required control data setting", "start conditions" and "start time chart" when creating
the program.
The following shows an example when a JOG operation is started for axis 1. ("[Cd.17]
JOG speed" is set to "100.00mm/min" in the example shown.)

Required control data setting

The control data shown below must be set to execute a JOG operation. The
setting is carried out with the sequence program.
Setting
value
0
Set "0".
Set a value equal to or below the "[Pr.31]
10000
JOG speed limit value".
Start conditions
The following conditions must be fulfilled when starting. The required conditions
must also be assembled in the sequence program, and the sequence program
must be configured so the operation will not start if the conditions are not fulfilled.
ON PLC CPU preparation completed
ON QD77MS preparation completed
ON All axis servo ON
ON
OFF Axis stop signal is OFF
OFF Start complete signal is OFF
OFF QD77MS is not operating
OFF There is no error
OFF M code ON signal is OFF
ON There is no forced stop input
OFF Stop signal is OFF
ON Within limit range
ON Within limit range
: If the PLC CPU is set to the asynchronous mode in the synchronization setting, this must be
inserted in the program for interlocking. If it is set to the synchronous mode, it must not be
inserted in the program for interlocking because it is turned ON when the PLC CPU executes
calculation.
Setting details
Signal state
QD77MS buffer memory
The access is possible.
11 - 10
Chapter 11 Manual Control
Buffer memory address
QD77MS2
QD77MS16
QD77MS4
1517+100n 4317+100n
1518+100n
4318+100n
1519+100n
4319+100n
n: Axis No.-1
Device
QD77MS2
QD77MS16
QD77MS4
Y0
X0
Y1
X1
Y4 to Y7
[Cd.180] Axis stop
X10 to X13 [Md.31] Status: b14
XC to XF
X10 to X1F
X8 to XB
[Md.31] Status: b13
X4 to X7
[Md.31] Status: b12