Restarting Speed After Speed Change Made During Position Control; Speed Change At New Speed Value "0" - Mitsubishi Electric QD77MS User Manual

Hide thumbs Also See for QD77MS:
Table of Contents

Advertisement

V
Fig. 13.22 Restarting speed after speed change made during position control
[QD77MS4 operation example]
Positioning start signal
[Y10, Y11, Y12, Y13]
BUSY signal
[XC,XD,XE,XF]
Cd. 14 New speed value
Cd. 15 Speed change request
Positioning operation
Speed change 0 flag
( Md. 31 status: b10)
(3) When the stop command was given to make a stop after a speed change
that had been made during position control, the restarting speed depends
on the "[Cd.14] New speed value".
Speed change
command
Stop command
(4) When the speed is changed by setting "[Cd.14] New speed value" to "0", the
operation is carried out as follows.
When "[Cd.15] Speed change request" is turned ON, the speed change 0
flag ([Md.31] Status: b10) turns ON.
(During interpolation control, the speed change 0 flag on the reference axis
side turns ON.)
The axis stops, but "[Md.26] Axis operation status" does not change, and
the BUSY signal remains ON. (If a stop signal is input, the BUSY signal
will turn OFF, and "[Md.26] Axis operation status" will change to
"stopped".)
In this case, setting the "[Cd.14] New speed value" to a value besides "0"
will turn OFF the speed change 0 flag ([Md.31] Status: b10), and enable
continued operation.
ON
OFF
ON
OFF
0
OFF
OFF
Fig. 13.23 Speed change at new speed value "0"
Restarting
command
1000
ON
ON
(Note): Refer to Section 3.3 for input/output signal of QD77MS16.
13 - 44
Chapter 13 Control Sub Functions
Da. 8
Command speed
Cd. 14 New speed value
t