Set with a decimal.
Setting value
K
1
The Simple Motion module resets the value to "0" automatically after the initial value setting
is completed. (Indicates that the initial value setting is completed.)
Set with a decimal.
Setting
K
value
Set with a hexadecimal.
H
Setting
value
Setting value
QD75MH initial value setting request
1: Requests QD75MH initial value setting.
SSCNET control command
0
: No command
(Note-1)
Axis No.
: Disconnect command of SSCNET
communication (Axis No. to be disconnected)
-2
: Execute command
-10
: Connect command of SSCNET communication
Except above setting : Invalid
(Note-1): QD77MS2 : 1 to 2
QD77MS4 : 1 to 4
QD77MS16: 1 to 16
Amplifier-less operation mode switching request
ABCDh: Change from normal operation mode to
amplifier-less operation mode
0000h : Change from amplifier-less operation
mode to normal operation mode
5 - 165
Chapter 5 Data Used for Positioning Control
Buffer memory address
(common for all axes)
Default
value
QD77MS2
QD77MS4
0
0
0000H
QD77MS16
1909
5909
1932
5932
1926
5926