8.4 Selection of the OPR setting condition

8.4.1 Outline of the OPR setting condition

Setting item
Function selection C-4
(PC17)
: Refer to Section 5.2.8 "Servo parameters" for information on the storage details.
If executing the home position return (OPR) when selecting "0: Need to pass servo
motor Z-phase after power on" with the servo parameter of the servo amplifier
"Function selection C-4 (PC17)", it is necessary that the servomotor has been rotated
more than one revolution and passed the Z phase (Motor reference position signal)
and that the zero point pass signal ([Md.108] Servo status (low-order buffer memory
address): b0) has turned ON.
When selecting "1: Not need to pass servo motor Z-phase after power on" with
"Function selection C-4 (PC17)", it is possible to turn the zero point pass signal
([Md.108] Servo status (low-order buffer memory address): b0) ON without passing the
zero point.
[Md.108] Servo status: b0

Data setting

To select the "OPR setting condition", set the "servo amplifier" shown in the
following table.
Servo parameters are set for each axis.
The "OPR setting condition" is stored into the following buffer memory addresses.
Setting
value
0 : Need to pass servo motor Z-phase after
0
1 : Not need to pass servo motor Z-phase
Precautions during operation
(1) Set "Function selection C-4 (PC17)", and then turn off the power supply of the
servo amplifier once and switch it on again to make that parameter setting
valid.
Buffer memory address (low-order)
QD77MS2/QD77MS4
876+100n
Setting details
power on
after power on
8 - 20
Chapter 8 OPR Control
QD77MS16
2476+100n
n: Axis No.-1
Buffer memory address
QD77MS2
QD77MS16
QD77MS4
30180+200n 28480+100n
n: Axis No.-1