CYLINDER HEADIVALVE
CAMSHAFT HOLDER DISASSEMBLY
Remove the stopper plugs and shims from the
camshaft holder (on some stopper plugs, the shims
are not used!.
NOTE:
Shim adjustment is necessary
if
the parts
listed on page 7·' are replaced. If the parts
are reused, mark the shims with felt-tip
pen so that they can be placed back to
their original locations.
Failure to place the shims back to their
original locations can cause tappet noises
or sticking valve.
Mark the camshaft holder components
during disassembly so they can be installed
in their original positions upon reassembly.
Remove the tappet adjuster from the camshaft
holder.
Remove the adjuster cap from the hole on the inlet
side.
NOTE:
Only the hydraulic valve adjusters controlling
the intake valve rocker arm shafts have caps.
7-8
~HONDA
~GL1200D'GLI200A
STPPER PLUGS AND SHIMS
STOPPER PLUGS AND SHIMS
HYDRAULIC TAPPET ADJUSTER
CAP