10. (Optional) For Allowed keep-alive misses, type the number of allowed keep-alive misses. The
default is 3.
11. Enable watchdog is used to monitor the connection to remote cloud services. If the
connection is down, you can configure the device to restart the connection, or to reboot. The
watchdog is enabled by default.
12. If Enable watchdog is enabled:
a. (Optional) For Restart Timeout, type the amount of time to wait before restarting the
connection to the remote cloud services, once the connection is down.
Allowed values are any number of hours, minutes, or seconds, and take the format
number{h|m|s}.
For example, to set Restart Timeout to ten minutes, enter 10m or 600s.
The minimum value is 30 minutes and the maximum is 48 hours. If not set, this option is
disabled. The default is 30 minutes.
b. (Optional) For Reboot Timeout, type the amount of time to wait before rebooting the
device, once the connection to the remote cloud servicesis down. By default, this option is
not set, which means that the option is disabled.
Allowed values are any number of hours, minutes, or seconds, and take the format
number{h|m|s}.
For example, to set Reboot Timeout to ten minutes, enter 10m or 600s.
The minimum value is 30 minutes and the maximum is 48 hours. If not set, this option is
disabled. The default is disabled.
13. (Optional) Enable Locally authenticate CLI to require a login and password to authenticate
the user from the remote cloud services CLI. If disabled, no login prompt will be presented and
the user will be logged in as admin. The default is disabled.
14. (Optional) Configure the IX10 device to communicate with remote cloud services by using SMS:
a. Click to expand Short message service.
b. Enable SMS messaging.
c. For Destination phone number, type the phone number for the remote cloud services.
d. (Optional) Type the Service identifier.
15. (Optional) Configure the IX10 device to communicate with remote cloud services by using an
HTTP proxy server:
a. Click to expand HTTP Proxy.
b. Enable the use of an HTTP proxy server.
c. For Server, type the hostname of the HTTP proxy server.
d. For Port, type or select the port number on the HTTP proxy server that the device should
connect to. The default is 2138.
16. Click Apply to save the configuration and apply the change.
  Command line
1. Select the device in Remote Manager and click Actions > Open Console, or log into the IX10