Digi IX10-00G4 User Manual page 194

Table of Contents

Advertisement

Serial port
b. Data bits: For Data bits, select the number of data bits used by the device to which you
want to connect. The default is 8.
c. Parity: For Parity, select the type of parity used by the device to which you want to
connect. The default is None.
d. Stop bits: For Stop bits, select the number of stop bits used by the device to which you
want to connect. The default is 1.
e. Flow control: For Flow control, select the type of flow control used by the device to
which you want to connect. The default is None.
1. Set the baud rate used by the device to which you want to connect:
(config)>path-parambaudrate rate
(config)>
2. Set the number of data bits used by the device to which you want to connect:
(config)>path-paramdatabits bits
(config)>
3. Set the type of parity used by the device to which you want to connect:
(config)>path-paramparity parity
(config)>
Allowed values are:
even
n
odd
n
none
n
The default is none.
4. Set the stop bits used by the device to which you want to connect:
(config)>path-paramstopbits bits
(config)>
5. Set the type of flow control used by the device to which you want to connect:
(config)>path-paramflow value
(config)>
where value is one of:
none
n
rts/cts
n
xon/xoff
n
8. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
IX10 User Guide
Configure Modbus mode
194

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ix10Ix10-00n4

Table of Contents