Configure The Device To Reboot When A Failure Is Detected - Digi IX10-00G4 User Manual

Table of Contents

Advertisement

Interfaces
14. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure the device to reboot when a failure is detected

Using SureLink, you can configure the IX10 device to reboot when it has determined that an interface
has failed.
Required configuration items
Enable SureLink.
n
SureLink can be enabled for both IPv4 and IPv6 configurations. By default, SureLink is enabled
for IPv4 for the preconfigured Modem interface. It is disabled for IPv6.
When SureLink is configured for Wireless WANs, SureLink tests are only run if the cellular
modem is connected and has an IP address. Use the SIM failover options to configure the IX10
device to automatically recover the modem in the event that it cannot obtain an IP address.
See
Configure a Wireless Wide Area Network (WWAN)
Enable device reboot upon interface failure.
n
The type of probe test to be performed, one of:
n
Test another interface's status: Used to create a failover or coupled relationship between
l
two interfaces. Requires the name of the alternate interface, the IP version to be tested,
and the expected status of the alternate interface (either up or down).
Ping: Requires the hostname or IP address of the host to be pinged.
l
DNS query: You can perform a DNS query to a named DNS server, or to the DNS servers
l
configured for the WAN.
HTTP test: Requires the URL of the host to be tested.
l
Test DNS servers configured for this interface: Tests communication with this interface's
l
DNS servers that are either provided by DHCP, or statically configured.
Interface status: Determines if the interface has an IP address assigned to it, that the
l
physical link is up, and that a route is present to send traffic out of the network interface.
Additional configuration items
See
Configure SureLink active recovery to detect modem failures
n
configuration parameters.
To configure the IX10 device to reboot when an interface has failed:
  Web
SureLink can be configured for both IPv4 and IPv6.
1. Log into Digi Remote Manager, or log into the local Web UI as a user with full Admin access
rights.
2. Access the device configuration:
Remote Manager:
IX10 User Guide
Wireless Wide Area Networks (WWANs)
for details about SIM failover.
for optional SureLink
80

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ix10Ix10-00n4

Table of Contents