Command line interface
Parameters
file: Firmware filename and path.

system power ignition off_delay

Update the current ignition off delay without changing the configuration.
Syntax
system power ignition off_delay <off_delay>
Parameters
off_delay: Ignition power off delay. Format: number{h|m|s}, Max: 18h. (Minimum: 0s, Maximum: 18h)

system restore

Restore the device's configuration from a backup archive or CLI commands file.
Syntax
system restore <path> [passphrase STRING]
Parameters
path: The path to the backup file.
passphrase: Decrypt the archive with a passphrase.

system script start

Run a manual script. Scripts that are disabled, not a manual script, or already running can not be run.
Syntax
system script start <script>
Parameters
script: Script to start.

system script stop

Stop an active running script. Scripts scheduled to run again will still run again (disable a script to
prevent it from running again).
Syntax
system script stop <script>
Parameters
script: Script to stop.

system serial clear

Clears the serial log.