Serial port
d. Stop bits: For Stop bits, select the number of stop bits used by the device to which you
want to connect. The default is 1.
e. Flow control: For Flow control, select the type of flow control used by the device to
which you want to connect. The default is None.
1. Set the baud rate used by the device to which you want to connect:
(config)>path-parambaudrate rate
(config)>
2. Set the number of data bits used by the device to which you want to connect:
(config)>path-paramdatabits bits
(config)>
3. Set the type of parity used by the device to which you want to connect:
(config)>path-paramparity parity
(config)>
Allowed values are:
even
n
odd
n
none
n
The default is none.
4. Set the stop bits used by the device to which you want to connect:
(config)>path-paramstopbits bits
(config)>
5. Set the type of flow control used by the device to which you want to connect:
(config)>path-paramflow value
(config)>
where value is one of:
none
n
rts/cts
n
xon/xoff
n
8. Click Apply to save the configuration and apply the change.
The Apply button is located at the top of the WebUI page. You may need to scroll to the top of
the page to locate it.