Hardware setup
Wire type: copper wire only
Terminal blocks torque: 5-7 pounds per inch
For supply connections, use wires suitable for at least 85° C.
Power installation must be performed by a qualified electrician, following the National
n
Electrical Code, ANSI/NFPA 70 and Canadian Electrical Code, Part I, CSA C22.1.
There must be a disconnect device in front of TX54 devices to protect maintenance workers.
n
Use a 20 A circuit-breaker as the disconnect device.
Before doing any maintenance, the maintenance worker must use caution and close the
n
general power supply.

TX54 power connector

The TX54 has a power connector located on the back of the device:
Pin
1
2
3
See
Connect power

Battery power management

When the TX54 device is used in a vehicle, Digi recommends that you use the ignition sense line. This
allows the device to properly shutdown when the vehicle is turned off. By default, the TX54 device
automatically powers on when it detects power on the ignition sensor, and powers off when it detects
that there is no power on the ignition sensor, and there is no delay for either power on or power off
based on the power ignition sensor.
You can configure delays for powering on or off the system based on the state of the ignition sensor.
See
Battery power management
TX54 User Guide
Connection
Ignition sensor
Positive
Negative
for information on connecting power to the device.
for details.
Connect power