Central management
To disable:
(config)> monitoring devicehealth only_send_deltas false
(config)>
When disabled, all metrics are uploaded every Health sample interval.
6. (Optional) Tuning parameters allow to you configure what data are uploaded to the Digi
Remote Manager. By default, all tuning parameters are enabled.
To view a list of all available tuning parameters, use the show command:
(config)> show monitoring devicehealth tuning
all
cellular
eth
serial
cellular
1
...
To disable a tuning parameter, set its value to false. For example, to turn off all reporting for
the serial port:
(config)> monitoring devicehealth tuning all serial rx bytes enabled
false
(config)> monitoring devicehealth tuning all serial tx bytes enabled
false
(config)>
TX54 User Guide
Collect device health data and set the sample interval
rx
bytes
enable true
tx
bytes
enable true
rx
bytes
enable true
tx
bytes
enable true
rx
bytes
enable true
tx
bytes
enable true
rx
bytes
enable true
packets
enable true
(config)>