System administration
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. At the config prompt, type:
(config)> system power input_voltage value
where value is one of:
12
n
l
l
24
n
l
l
9-36
n
l
l
4. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
5. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Power ignition sensor
When the TX54 device is used in a vehicle, Digi recommends that you use the ignition sense line. This
allows the device to properly shutdown when the vehicle is turned off.
This section contains the following topics:
Configure power delays for power ignition sensor
TX54 User Guide
Powers up if input power is above 11.5 volts.
Powers down if input power drops below 10.5 volts.
Powers up if the input power is above 23 volts.
Powers down if the power drops below 21 volts.
Powers up if the input power is above 8.5 volts.
Powers down if the input power drops below 8 volts.
Power ignition sensor
842
841