Central management
6. Click Apply to save the configuration and apply the change.
  Command line
1. Log into the TX54 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Device health data upload is enabled by default. To enable or disable:
To enable:
n
(config)> monitoring events enable true
(config)>
To disable:
n
(config)> monitoring events enable false
(config)>
4. The interval between event log uploads is set to 60 minutes by default. To change:
(config)> monitoring events interval value
(config)>
where value is one of 1, 5, 15, 30, or 60, and represents the number of minutes between
uploads of health sample data.
5. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
6. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Log into Digi Remote Manager

To start Digi Remote Manager
1. If you have not already done so, click
2. Check your email for Digi Remote Manager login instructions.
TX54 User Guide
here
to sign up for a Digi Remote Manager account.
Log into Digi Remote Manager