Stop Capturing Packets - Digi TX54 User Manual

Hide thumbs Also See for TX54:
Table of Contents

Advertisement

Diagnostics
  Command line
1. Log into the TX54 command line as a user with Admin access.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. Type the following at the Admin CLI prompt:
> analyzer start name capture_filter
>
where capture_filter is the name of a packet capture configuration. See
capture for the network analyzer
To determine available packet capture configurations, use the ?:
> analyzer start name ?
name: Name of the capture filter to use.
Format:
test_capture
capture_ping
> analyzer start name
You can capture up to 10 MB of data traffic in two 5 MB files per interface.
Note
Data traffic is captured to RAM and the captured data is lost when the device reboots unless you
save the data to a file. See

Stop capturing packets

You can stop packet capture at the command line with the
To stop packet capture from the command line:
  Command line
1. Log into the TX54 command line as a user with Admin access.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. Type the following at the Admin CLI prompt:
> analyzer stop name capture_filter
>
where capture_filter is the name of a packet capture configuration. See
capture for the network analyzer
To determine available packet capture configurations, use the ?:
> analyzer stop name ?
TX54 User Guide
for more information.
Save captured data traffic to a
for more information.
Analyze network traffic
Configure packet
file.
analyzer stop
command.