4 Repair
4.4.2 Replacement of wrist unit
Continued
3
4
5
6
7
8
9
10
Refitting
1
Continues on next page
214
Action
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
Remove all equipment fitted to the wrist unit.
Remove the cover, wrist unit in order to reach the
cable harness.
Note
Foundry Plus
Make sure not to lose the washers placed in the
holes of the Foundry Plus gasket.
xx1400002580
Remove the cable harness, axes 5 and 6.
CAUTION
The complete wrist unit weighs 96 kg! All lifting
equipment used must be sized accordingly!
Secure the wrist unit with a roundsling in an over-
head crane.
Unscrew the eight attachment screws securing the
wrist unit.
Remove the wrist unit from the upper arm by moving
it a little back and forth until it is lose.
Action
Secure the wrist unit with a roundsling in an over-
head crane and lift it to its mounting position.
© Copyright 2006-2020 ABB. All rights reserved.
Note
Shown in the figure in
Location of
wrist unit on page
212.
Shown in the figure
Location of
wrist unit on page
212.
Detailed in section
Replacement
of cable harness, upper end on
page
187.
Shown in the figure
Location of
wrist unit on page
212.
Note! Do not damage the cylindric-
al pin in the process.
Note
Product manual - IRB 6620