Delta C200 Series User Manual page 99

Intelligent vector control drive
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
Parameter
11-29
11-30
11-31
11-32
11-33
11-34
11-35
11-36
11-37
11-38
11-39
Call 1(800)985-6929 for Sales
Explanation
Torque Offset Setting
High Torque Offset
Middle Torque Offset
Low Torque Offset
Source of Torque
Command
Torque Command
Filter Time of Torque
Command
Speed Limit Selection
Forward Speed Limit
(torque mode)
Reverse Speed Limit
(torque mode)
Zero Torque Command
Mode
deltaacdrives.com
Chapter 10 Summary of Parameter Settings|C200 Series
Settings
0~100%
0~100%
0~100%
0~100%
0: Digital keypad
1: RS-485 communication (Pr.11-34)
2: Analog input (Pr.03-00)
3: CANopen
-100.0~+100.0% (Pr.11-27=100%)
0.000~1.000sec
0: Set by Pr.11-37 (Forward speed limit) and Pr.11-38
(Reverse speed limit)
1: Set by Pr.11-37,11-38 and Pr.00-20 (Source of
Master Frequency Command)
2: Set by Pr.00-20 (Source of Master Frequency
Command).
0~120%
0~120%
0: Torque mode
1: Speed mode
10-31
deltaacdrives.com
sales@deltaacdrives.com
Factory
Setting
0.0
30.0
20.0
10.0
0
0.0
0.000
0
10
10
0
sales@deltaacdrives.com

Advertisement

Table of Contents
loading

Table of Contents